Browse all practice questions for the New York City Refrigeration License Exam I Practice. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

New York City Refrigeration License Exam I Practice course image
More practice questions

These questions are part of the practice quiz. Start practicing

  • Inlet moisture in a steam turbine should be kept low primarily to minimize wear on:
  • An automatic expansion valve maintains a constant what in the evaporator?
  • Why is a refrigerant gauge called a compound gauge?
  • Which property is desirable to maximize energy storage during the refrigerant’s phase change?
  • With a 75 degree dry bulb and a 73 degree wet bulb the relative humidity is?
  • When a steam turbine reaches critical speed, the immediate mechanical response is typically?
  • Critical speed in turbine operation is best described as a condition where the machine experiences what?
  • A campus refrigeration system with noisy condenser water pump #1, fluctuating discharger gauge, and hot motor: what action should you take?
  • The purpose of chemical additives in cooling tower water is to:
  • Capacitors are used on refrigerant motors. Which statement describes their function?
  • For proper metering, where should the TXV sensing bulb be mounted?
  • A TXV is used to maintain constant evaporator superheat by regulating what?
  • A circuit breaker has a similar function as what?
  • An inline refrigerant handling system suitable for a centrifugal compressor using R123 is used primarily to recover refrigerant for reuse. This system is called:
  • A reciprocating compressor cylinder has a 10 inches bore and 14 inches stroke. The volume of refrigerant, in cubic inches, will be closer to:
  • Under what condition would an FDNY permit be required for hot work?
  • Which consequence is most likely when a rotating turbine is driven through its natural frequency?
  • Which valve is mounted on the top of the valve plate in a typical reciprocating compressor?
  • An electrically operated control requires 24 volts to operate. To reduce 110 volts to 24 volts you will need:
  • Ammonia refrigerant ASHRAE classification is which?
  • From four valve types, which is most effective for controlling pressure in a refrigeration system?
  • A pipe with 6 feet in diameter and 8 feet long contains approximately how many gallons?
  • The most likely cause of condenser water pump cavitation is:
  • In the standard liquid-line sequence, which component provides a visual indication of liquid refrigerant presence?
  • The suction pressure of a reciprocating compressor is 65 PSIG and the discharge pressure is 120 PSIG. The atmosphere is 14.7 PSIG. The compression ratio is closest to:
  • Why are copper and aluminum commonly used for condenser tubes in refrigeration systems?
  • A muffler in a refrigeration system is installed between which two components?
  • What is the minimum requirement an engineer needs to log readings?
  • To convert water at 32°F to ice at the same temperature, what must the refrigeration system remove?
  • Which symptom directly indicates a turbine has reached critical speed?
  • If the condenser water pump fails, what is the most likely immediate effect on the refrigeration cycle?
  • When charging refrigerant on the low side of a reciprocating machine with manifold gauges, what is the position of the manifold?
  • Regarding the functioning of a steam turbine, why is it advisable to keep moisture in the inlet as low as possible?
  • The vessel used for refrigerant recovery is intended for use in which refrigerant-related process?
  • What type of sprinkler system needs inspecting?
  • In a reciprocating system, compressor discharge temperature dropped significantly and suction line pressure is high. Which valve condition may cause this?
  • Which of the following does not require flame resistant treatment?
  • A refrigeration unit uses a low-side float valve as a metering device and is experiencing short cycling. What does this likely indicate?
  • In order for a refrigerant to become superheated it must be heated in a section of the low-side refrigerant line:
  • In the listed sequence of components on the liquid line from condenser to TEV, which component appears last?
  • Which condenser condition contributes to greater refrigerant cycle efficiency?
  • What type of heat is removed from the refrigerant in a condenser?
  • Which option describes the function of the equipment that removes non-condensables from the condenser?
  • Given gauge suction pressure 3 psi, gauge discharge pressure 10 psi, atmospheric pressure 14.7 psi. The ratio of absolute discharge pressure to absolute suction pressure is closest to:
  • Which condition can lead to a starved evaporator in a refrigeration system?
  • Should you be concerned about a 55F chilled water supply used for human comfort, and why?
  • What is the advantage of a shell and tube condenser, as opposed to a shell and coil condenser?
  • Which valves control the water level in the surface condenser hot well of a steam turbine?
  • Under normal operation, what is the state of refrigerant entering the compressor?
  • Filter driers remove:
  • Which ASHRAE refrigerant classification would FDNY consider most hazardous in a fire situation?
  • How long must a Fire alarm log book be kept?
  • Modern compressors usually seal the rotating shaft as it exits the compressor housing with a spring seal made of:
  • Which instrument is specifically used to measure electrical resistance to diagnose winding faults in motors?
  • If R134A accidentally touches a refrigerant engineer's skin, what first aid should be applied?
  • From the condenser to the TEV, what is the correct order of liquid-line components?
  • The function of the safety head on a compressor is to prevent what issue?
  • Which event would indicate that the cooling tower is not being air-cooled effectively?
  • What is the primary method used to control capacity in a centrifugal compressor?
  • Which information is not contained in a Material Safety Data Sheet (MSDS)?
  • Which safety feature relieves overpressure in a low-pressure centrifugal refrigeration system?
  • Is it permissible to chain an exit door under any circumstances?
  • Which device protects a steam turbine from excessive speed, preventing overspeed conditions?
  • If a cube has 12-inch sides, its volume in cubic feet is?
  • As an engineer you notice pressure drops across the evaporator. You check and notice the external equalizer line is disconnected. What will occur in the evaporator?
  • Manifold hoses should be equipped with which fittings?
  • If the cooling tower is on the 8th floor, how many feet above the first floor is it?
  • In refrigerant management, which term describes extracting refrigerant and cleaning it for reuse without reclamation requirements?
  • A single phase 208 VAC circuit has 2 hot wires, the third is the?
  • If all liquid has been recovered from a system to be overhauled, what is the recommended pre-opening procedure?
  • What is the lowest temperature a cooling tower can operate at?
  • There is 7.48 gallons per cubic foot. How many gallons of water are in a pipe 8 feet in diameter and 10 feet long?
  • Standpipe certificate should be available for which authorities?
  • Which statement about forced-draft cooling towers is true?
  • A condenser pump circulates water at 85F in, 88F out. If the condenser pressure is high while tubes are clean, which is a likely cause?
  • How would you calibrate a thermometer?
  • If a centrifugal compressor has suction pressure of 3 psi and discharge pressure of 10 psi, with atmospheric pressure 14.7 psi, the ratio of absolute discharge pressure to absolute suction pressure is closest to:
  • Why is a pressure relief valve considered better than a fusible plug?
  • Which statement best characterizes a hermetic compressor?
  • If a sprinkler system has been off-line for two days, how often should it be inspected until it is back in service?
  • Where is the charging valve typically located in a large R134A system?
  • During hot works near a sprinkler head, what should you do to prevent the fire alarm from triggering?
  • If the diameter of a pipe increases while keeping the length constant, how does the volume of the pipe change?
  • A low side float valve is used to maintain what?
  • When you are finished leak testing with R22 and nitrogen the next step would be?
  • There is 7.48 gallons per cubic foot. How many gallons are in a pipe 10 feet in diameter and 5 feet long?
  • In a multi-stage centrifugal compressor, which statement about the stages is correct?
  • In a steam turbine system, how is the water level controlled in the surface condenser hot well?
  • If a panel on a large centrifugal refrigeration system indicates a water flow problem, what is the recommended first step?
  • If a cold front causes a sudden temperature drop, the thermostat will cause the solenoid valve to do what?
  • R134A is described as which of the following according to MSDS?
  • If the insulation on the thermal bulb line to the suction pipe near the evaporator fails in a room at 85F, what is the likely consequence?
  • Which item is not required to have flame resistant treatment?
  • In a cascade refrigeration system, what is the primary reason to use at least two compressors?
  • Standpipe certificates should be available to which parties?
  • A solenoid valve opens when what occurs?
  • An engineer suspects a short in the motor windings has caused the motor to trip on overload. What instrument should be used to check the motor?
  • During unloading, what valve condition is maintained?
  • If a valve handle is at a 45-degree angle, what is the valve's position?
  • What is the minimum frequency for an engineer to log readings during a shift?
  • The charge in a TEV sensing bulb is?
  • A pipe with 8 feet in diameter and 12 feet long contains approximately how many gallons?
  • A starved evaporator is most likely caused by which condition?
  • A FDNY permit is required to conduct hot works under which condition?
  • Which component is commonly found in a pump discharge path to prevent backflow?
  • Which component on manifold hoses helps minimize refrigerant loss?
  • Which ASHRAE refrigerant safety classification denotes the most flammable?
  • What must operators monitor to prevent damage when a turbine may approach critical speed?
  • Liquid refrigerant that has passed through a metering device is?
  • Which device is intended to limit refrigerant loss during relief events?
  • What action is recommended when instrumentation detects a sudden rise in vibration near the turbine's operating range?
  • Which device maintains the level of the refrigerant in the evaporator?
  • What is the most important requirement for an evaporator to function effectively?
  • Compared with a simple straight-tube condenser, a shell and coil condenser is typically favored for its?
  • Which factor should be considered to ensure safe operation when replacing a high-side gauge?
  • Under normal condition, the refrigerant enters the compressor as a:
  • A water chiller with a reciprocating compressor, a thermostatic expansion valve and an air cooled condenser. A restriction in the liquid line would result in:
  • Where must Material Safety Data Sheets be located?
  • Which component is listed as the first element in the liquid line sequence from condenser to TEV?
  • A motor winding is touching the inside of the motor housing. This could result in:
  • Which of the following describes the rated cooling capacity of a 30-ton system?
  • How long does it take to warm up a steam turbine?
  • What is the radius of a pipe with a 12-inch diameter?
  • How is the compressor safety head best described?
  • In a condenser system, energy balance states total heat rejected equals heat picked up in evaporator plus heat of compression. Which statement describes this energy balance?
  • What is a compressor safety head?
  • When is a chemical fire extinguisher system needed?
  • Fireproof decorations in buildings are useful for?
  • In a hermetic compressor, the motor is enclosed in a gas-tight housing along with the compressor.
  • What component is primarily responsible for controlling turbine speed by adjusting steam admission?
  • In the absence of water chemical treatment of a cooling tower, what should you do?
  • In a chilled water system with an air-cooled condensing unit on a roof during cold weather, what type of protection is used?
  • Copper tubing refrigerant lines must be installed for a new system. To prevent collapse at bends, which tool should the refrigerant engineer use?
  • What is the cooling medium for an evaporative condenser?
  • In a multi-cylinder reciprocating compressor that uses cylinder unloaders to regulate capacity, what would occur if some unloaders fail to operate when needed?
  • Why is it important to avoid reaching critical speed in a steam turbine?
  • For charging a 60-ton plant with R134A, where is the charging valve most likely located?
  • Which component is responsible for maintaining evaporator superheat in a chilled refrigerant system?
  • Which property is desirable in a refrigeration system to optimize energy storage during phase change?
  • In a cooling system, neglecting condenser water treatment would most directly raise which indicator first?
  • If water treatment is neglected in a refrigerant system, condenser pressure tends to rise.
  • Which document would you consult to understand the hazards, safe handling, and first aid measures for a chemical used in the refrigeration plant?
  • You notice condenser water coming back from the 9-cell cooling tower at 90F; to bring to 85F, which immediate action would you take?
  • In relation to the suction pressure of a compressor, the oil pressure gauge should read approximately what relative value to suction pressure?
  • Electric defrosting devices used with evaporator units are classified as which type of component?
  • The total heat to be removed by the condenser equals the heat picked up in the evaporator plus what?
  • The inline refrigerant cleaning system is advisable to
  • To bring an additional pump online in a multi-pump system, what sequence should be followed?
  • In a water chiller system using refrigerant R123, a leak in the evaporator shell is most likely to cause which condition?
  • While operating an R-22 single acting compressor system, oil foaming in the crankcase is most likely caused by a:
  • In Phase II fireman's service, who is allowed to control the elevator?
  • What is the cross-sectional area, in square inches, of a pipe with a 12-inch diameter?
  • If refrigerant water and oil are observed together in a container, the fluids would settle from top to bottom as:
  • What is the primary reason ribbed metal piping is used for electrical wires connected to the refrigeration system?
  • A BTU is a unit of heat. If 10 BTU are transferred to 10 pounds of water, the water temperature rise will be closest to:
  • What is the function of the oil charging port on a compressor?
  • Which refrigerant type requires FDNY approval?
  • Which device on a compressor is used to manage lubrication by adding or removing oil?
  • You find that the check valve on a centrifugal pump is leaking. When would the most damage be caused to the pump?
  • What is the function of the vacuum breaker in a steam turbine?
  • ASRHAE refrigerant safety group classification system is based on which two characteristics?
  • Which symptom most reliably indicates an undercharged refrigerant system?
  • In a large centrifugal refrigeration system, if the cooling tower water level is very low, what is a common initial corrective step?
  • If 29.92" Hg is equal to 14.7 psia, then 26" Hg converts to what is psia?
  • In a steam turbine, what is the function of the Kingsbury thrust bearing?
  • A leak in the evaporator shell of an R134A system is likely to cause what protective action?
  • All liquid has been recovered from a system to be overhauled; the system
  • Oil collected in an oil separator is generally returned to which component?
  • A centrifugal water pump is considered to be fully primed when
  • A refrigeration system controlled by a TXV shows high discharge pressure and high normal sub-cooling. What is the most probable cause?
  • If a refrigerant temperature chart uses Celsius and 4°C equals 39.2°F, what is the Fahrenheit equivalent?
  • If a condenser water pump shows noise, fluctuating gauge readings, and the motor runs hot, the recommended action is:
  • Information about the physical and chemical properties of a hazardous material can be found in which document?
  • What is used on an outside pipe to prevent freezing?
  • During a cooling tower check on a large refrigeration system, if the tower cells have very low water levels, which immediate action is appropriate?
  • In an indirect refrigeration system, which would not be used as a cooling medium for the building spaces?
  • If the discharge pressure of the condenser water pump is significantly lower than normal, which action would you avoid taking?
  • An inline refrigerant cleaning system is advisable to
  • Liquid level gauge glasses (except bull's eye) are generally equipped with which type of valve?
  • To isolate a dual pressure relief valve while the system remains in service, which valve type should be used?
  • How are the suction and discharge valves of a reciprocating compressor typically mounted relative to the valve plate?
  • The condenser pump is on the first floor and not running. The pressure gauge shows 55 psi. There is 15 feet for each floor. What floor is the cooling tower on?
  • What type of refrigerant is found inside the machine's gauges?
  • Subcooling of the refrigerant occurs in which component of the refrigeration system?
  • When replacing a gauge on the high side, the pressure graduation should be at least how many times the design pressure?
  • How does a cylinder unloader operate on a reciprocating compressor?
  • What is the function of the turbine auxiliary oil pump?
  • Which refrigerant safety classification indicates no flammability and lower toxicity?
  • Which of the following is NOT typically considered a pump component?
  • In a building with a multilane standpipe system, how does each zone get water supply?
  • R-123 refrigerant is classified as which type of refrigerant?
  • What is the correct interpretation of a centrifugal pump being fully primed?
  • In a reciprocating refrigeration system, the refrigerant at the inlet to the compressor is typically in which state?
  • Which component does not typically vary refrigerant flow in a system?
  • The heat removed in a condenser consists of
  • Of the following, centrifugal refrigerant machine is best characterized by:
  • What is the purpose of steam ejectors on the surface condenser of a turbine-driven system?
  • What is one of the pre hot-work procedures performed before hot works?
  • How much does 2.5 gallons of water weigh?
  • The Kingsbury thrust bearing in a steam turbine is designed to maintain which type of shaft alignment?
  • How often must emergency power testing be performed?
  • A refrigeration engineer notes excessive cycling of the temperature control on a reciprocating compressor unit. The crankcase temperature is high, the discharge temperature is low, and the suction line temperature is high. Which fault is most likely causing these conditions?
  • How do you start a centrifugal chiller?
  • In rotating machinery, what sign is most indicative of crossing the critical speed?
  • Where is the most likely time for damage to occur if a centrifugal pump's check valve leaks?
  • Where must fire alarm books be kept?
  • Which unit is commonly used to specify a refrigerant charge for small systems?
  • If a refrigerant saturation pressure gauge is used in a system with chilled water, the reading primarily indicates the temperature of which component?
  • In a cascade system, adding a second compressor mainly helps to prevent what?
  • A technician has been asked to estimate the cost of operating a 5 horse power motor. Because the plant is build by energy consumed as kilowatt-hours, the technician will have to calculate the conversion. The equivalent in energy of a 5 core power motor operating 9 hours in kilowatt-hours is closest to:
  • A refrigeration compressor has failed to start. After verifying that the electrical circuit to the motor, including all switches and circuit breakers, is complete, the next item to check would likely be which?
  • If the resistance in a circuit is cut in half, how does the power factor change?
  • What is not required to be serviced annually?
  • A superheated vapor is a:
  • FDNY is most concerned with which ASHRAE refrigerant classification?
  • In a parallel setup with two centrifugal condenser water pumps, one at max capacity, what is the most likely effect if you throttle back the discharge of the other pump?
  • What is the device used to measure the speed of a turbine?
  • In a refrigeration system that uses chilled water as the cooling medium, a gauge reading the refrigerant saturation pressure is most useful for estimating which of the following?
  • What is the most likely reason for frost on the suction line and part of the compressor?
  • What is the primary risk when a turbine hits its critical speed?
  • The cooling medium for a cooling tower is?
  • On a steam turbine, which factor could cause the atmospheric valve to open?
  • Which device is commonly used to modulate refrigerant flow by varying the amount of liquid refrigerant admitted?
  • What is the main advantage of a forced-draft cooling tower over a natural-draft cooling tower?
  • Which statement correctly identifies the starting point for relief valve operation?
  • The sole refrigeration engineer on duty may leave the building’s refrigeration system when it is operating only when?
  • After recovering liquid refrigerant from a centrifugal chiller the next step is to?
  • What maintenance action is recommended when a cooling tower lacks water chemical treatment?
  • What does a wiring diagram display?
  • Of the following, centrifugal chillers are best described as?
  • In a multi-stage centrifugal compressor, which statement is true about the stages?
  • When will the BTU transfer between evaporator and condenser be greatest?
  • What is the most widely used regulation book by operating engineers?
  • Capacity control of a reciprocating hermetic compressor is typically achieved through the operation of which component?
  • Which of these compressors is not a positive displacement type?
  • A decrease in the efficiency of a reciprocating compressor is most likely caused by which of the following?
  • Under the New York City fire code, refrigerant storage containers must be approved by which organization?
  • What is most accurate about fire alarm books?
  • The ratio of the actual vapor pressure to the saturated vapor pressure at a given temperature defines what?
  • The amount of refrigerant flowing through economizer orifices is determined by
  • The flash point of compressor lubricating oil should be:
  • Which refrigerant in commercial and industrial systems has the highest latent heat and refrigerating effect?
  • A high-side float valve is used to maintain what in the evaporator?
  • The flash point relationship for compressor oil must be:
  • What is the primary purpose of oil in a refrigeration machine?
  • What type of refrigerant do you need FDNY approval for?
  • Electrical current is measured in which quantity?
  • Which sequence correctly describes the startup steps for a centrifugal chiller?
  • Cooling tower water additives are used to:
  • Under which arrangement of evaporator and condenser temperatures would the BTU transfer be the greatest?
  • Centrifugal pressure is determined by?
  • Which valve arrangement allows maintenance on a relief valve while the system remains in service?
  • The purpose of wear rings in a centrifugal pump is to:
  • What is the function of a safety head on a compressor?
  • What specific data is provided on a fusible plug used in condensers?
  • To maximize evaporator effectiveness, what characteristic should it possess?
  • In cooling tower operation, which temperature reading is used to specify the lower limit?
  • In a multilane standpipe system, how is water supplied to each zone?
  • Which type of compressor is typically controlled by a hot gas bypass valve for capacity control?
  • A box measures 12 inches by 12 inches by 12 inches. What is its volume in cubic feet?
  • Centrifugal chillers are best described as units with which combination of tonnage and operating pressure?
  • The suction service valve of a reciprocating compressor is front seated and the machine runs until the low pressure cut-out shuts the compressor off. When the machine is stopped, suction pressure tends to rise rapidly. What is the most probable cause?
  • How much additional refrigerant is allowed in a machine room?
  • Where is the muffler located?
  • The primary way of achieving capacity control of a centrifugal compressor is:
  • Clogged air louvers under an induced draft cooling tower will produce which result?
  • Water regulating valves are used to?
  • Which type of refrigerant system is least likely to leak refrigerant into the building space being cooled?
  • What is the standard cooling medium for an evaporative condenser?
  • Under NYC fire code, refrigerant storage containers must be approved by which organization?
  • A 30-ton cooling system removes how many BTU per hour?
  • During a routine line inspection, the TXV bulb is found on the floor. Where should the bulb be attached for proper meter operation?
  • What is the primary purpose of installing a muffler on a reciprocating refrigerant machine?
  • A water pump with a discharge head of 92 feet of water corresponds to approximately how many psi?
  • A psychrometer is used by refrigeration engineers to measure:
  • What typically happens to suction pressure after a reciprocating compressor is shut down on a low-pressure cut-out?
  • If expansion valve is opened too wide, which of the following system conditions may result?
  • When an expansion valve is operating properly, at the end of the evaporator will contain what?
  • In indirect low-temperature refrigerant systems, using glycol as the intermediate cooling medium instead of salt brine provides which main advantage?
  • The process by which refrigerant is extracted and cleaned for reuse without requirements for reclamation is called:
  • An equalizer line on a TXV is used to:
  • A condenser water pump is connected to a suction pipe 75 feet long and 12 inches in diameter. If this pipe is completely drained, approximately how many gallons of water will be obtained?
  • Which outcome is associated with critical speed in rotating machinery like turbines?
  • In a three-ton capacity reciprocating commercial refrigeration system, the most common metering device is what?
  • You are operating a 2,000 ton steam-driven turbine centrifugal system providing 46 F chilled water; one building is unsatisfied. What action should you take?
  • Which type of pump is commonly used to move chilled water in a central cooling system?
  • What is the responsibility of a B29 COF holder?
  • On a refrigerant chart using Celsius, if the temperature reads 5 degrees, what is the corresponding Fahrenheit temperature?
  • What device automatically controls the speed of a steam turbine?
  • An engineer would expect a relief valve to start function at a pressure:
  • If water treatment is not maintained for a refrigerant system, what is the most likely result?
  • The amount of electrical power used to operate a solenoid valve or a motor is measured in what unit?
  • According to code, emergency power is not required in which setting?
  • What is the function of gland steam in a turbine?
  • Which condenser design is noted for having less danger of leaks?
  • A reciprocating compressor is making a knocking sound during operation. If worn parts are not the cause, what is probably the reason?
  • The oil collected in an oil separator is typically returned to which component?
  • In a multi-stage centrifugal compressor, the volumes of the stages are typically which of the following?
  • The viscosity of lubrication oil is described by a number. A low viscosity number describes oil that:
  • Which description best matches a standpipe hose outlet?
  • Gland steam is used to seal which part of a steam turbine?
  • Which device is used on an outside pipe to prevent freezing?
  • Regardless of ASHRAE refrigerant classification, if there is a refrigerant leak, which hazard should the engineer be aware of?
  • Which option best explains why ribbed metal conduit might be used for wiring near a refrigeration system?
  • What is ammonia's refrigerant ASHRAE classification?
  • A standpipe system will be out of service for two days. How long should there be a fire watch?
  • Which of the following describes the effect of critical speed on a steam turbine?
  • Copper and aluminum are frequently used for condenser tubes in refrigeration systems because of which property?
  • Cross connections and standpipe risers must be painted what color?
  • According to MSDS, R134A is described as a
  • Which statement about centrifugal compressors is true?
  • To improve the efficiency of the centrifugal refrigerant compressor, which action is beneficial?
  • What happens when a steam turbine reaches critical speed?
  • What is the state of refrigerant entering the compressor on a reciprocating machine?
  • Which situation is most likely to cause high condenser pressure despite clean tubes?
  • If two condenser water pumps run in parallel and one pump is throttled, what is the effect on total flow to the condenser?
  • Under what condition is a centrifugal water pump called a lift pump?
  • Non-condensable gases traveling with refrigerant usually accumulate in which component?
  • During charging, what is the primary reason for performing a thorough evacuation?
  • A chilled water pump is cavitating. Which of the following is the most likely cause?
  • A rooftop cooling tower connected to a basement pump shows 140 PSIG at the pump inlet with the pump off. The corresponding water column height is closest to which value (feet)?
  • In the event of a refrigerant escape, which hazard should be considered regardless of refrigerant type?
  • What does the drip from the packing gland indicate in a centrifugal pump?
  • Reaching the critical speed in a steam turbine most directly leads to which condition?
  • The condenser rejects heat equal to the evaporator heat plus the heat of compression. Which two contributions make up the total heat rejected by the condenser?
  • Which practice helps avoid water and moisture problems in a refrigerant system?
  • An inline refrigerant cleaning system that may be used with a centrifugal compressor containing R123 refrigerant is:
  • During Phase II fireman's service, which statement is correct?
  • A wiring diagram primarily shows what in an HVAC system?
  • During operation, engineers monitor to detect potential critical speed by observing what?
  • Regarding fire safety, which ASHRAE refrigerant safety classification indicates no flammability and lower toxicity?
  • Neglecting condenser water treatment, the first operational symptom is what?
  • A refrigeration system uses a jet ejector to raise settled oil mixed with refrigerant to the oil pump. If a restriction in the refrigerant flow to the jet ejector develops, what condition may occur?
  • The most important reason to sub-cool the refrigerant in the condenser is to ensure that which occurs?
  • The rupture disc for a low-pressure centrifugal refrigeration machine is normally located on the:
  • In a refrigeration system where a low-side float valve is used, what is the primary role of that valve?
  • In indirect low-temperature refrigerant systems, using glycol as the intermediate cooling medium offers which main advantage?
  • Electric defrost devices used on evaporators are classified as which type of heating element?
Subscribe

Get the latest from Passetra

You can unsubscribe at any time. Read our privacy policy